Helium Leak Detector


The instrument is primarily useful for the vacuum leak testing of UHV components, chambers, enclosures, vacuum sealings, large experimental facilities etc.


The instrument is primarily useful for the vacuum leak testing of UHV components, chambers, enclosures, vacuum sealings, large experimental facilities etc.

SALIENT FEATURES

  • Measurement range : 10(-4) torr-l/s to 10(-10) torr-l/s & 10(-7) torr-l/s(sniffer).
  • Response time: ~ 1sec.
  • Modes of operation: Vacuum, Sniffer.
  • Fully automatic operation.

APPLICATIONS

  • For leak measurement of vacuum components used in accelerators, analytical instruments, various plants using gaseous system, pressure chambers etc.

The instrument is primarily useful for the vacuum leak testing of UHV components, chambers, enclosures, vacuum sealings, large experimental facilities etc. The basic principle involves three different components viz., an ionization source along with suitable ion-optics, mass analyzer and ion detector- all supported by suitable electronics and vacuum. The job under investigation for leak is connected with the leak detector. Helium is sprayed on the suspected parts and enters through the leak into the detector spectrometer. The helium ions are generated by electron impact which are accelerated, focused and deflected by a magnet analyser to the Faraday collector. The ion current so collected is measured and calibrated to indicate the leak rate of Helium to establish the presence and also level of the leak. It is a highly reliable and widely used method for leak testing applications.


SALIENT FEATURES

  • Measurement range : 10(-4) torr-l/s to 10(-10) torr-l/s & 10(-7) torr-l/s(sniffer)
  • Response time: ~ 1sec
  • Modes of operation: Vacuum, Sniffer
  • Fully automatic operation

APPLICATIONS

  • For leak measurement of vacuum components used in accelerators, analytical instruments, various plants using gaseous system, pressure chambers etc.

DETAILED SPECIFICATIONS

General

  • Dimensions : 700 mm (L) x 500 mm (W) x 1000 (H)
  • Weight : 50 kg
  • Test Connection : 25 ISO KF
  • Main Voltage : 220 V
  • Mains Frequency : 50 Hz
  • Mains Current : < 10 A
  • Power : < 1 kW

Ion Source

  • Type : Electron bombardment
  • Filament : Tungsten Wire (5 mil diameter)
  • Accelerating Potential : 450 volt
  • Geometry : Nier Type
  • Electron beam focusing : by permanent magnet (Field : ~ 100 gauss)

Analyser

  • Type : Permanent Magnet (Ferrite)
  • Geometry : Normal
  • Bending Angle : 180 deg
  • Radius : 5 cm
  • Magnetic Field : 1500 gauss

Collector

  • Type : Faraday
  • Opening Size : 3mm width x 10 mm height
  • Measurement system : Electrometer amplifier
  • Gain Resistance : 1 x 10(12) ohm
  • Time constant : 1 sec

Vacuum system

  • Vacuum pump (MS) : TMP with pumping speed 30 L/s
  • Vacuum pump (backing) : Rotary pump (Pumping speed: 5 m3/h)
  • Valve manifold : Aluminium make with 7 ports
  • Valve type : Electromagnetic
  • Valve leak tightness : < 1x 10(-8) torr L/s
  • Modes : Counter flow, Main flow, sniffer

Software

  • Operation : Auto start/stop, leak measurement
  • Mode selection : Semi automatic

INFRASTRUCTURE REQUIRED

  • Mechanical fabrication workshop with lathe machine, Milling machine, TIG welding, Insulation and HV tester.

Electronic Lab Facility for Testing Purpose

  • PCB assembly & instrument rack wiring facility.
  • Measuring instruments like 6 and 1/2 digit precision digital multimeter & Oscilloscope, Function Generator

Raw Material

  • Most of the components are available within the country and some components (Tungsten wire, vacuum pumps etc.) need to be imported through local agents.
SR NO. Organization name Licensee Name Licensee Code ACQUIRED ON Valid Till Address City State Email Phone
01 M/S. TRIUMPH DESIGN CORPORATION Mr. KAMAL R. PANCHAL, Mr. HIREN R. PANCHAL 36 24-07-2018 24-07-2025 208, Shiv Sagar Ind Est., Kotkar Road, Goregon (E) Mumbai Maharashtra kamal@triumphdesign.in 9820527156
02 Spitzen Analytic Instruments Pvt. Ltd. Mr. Shine Damodaran 537 23-03-2022 22-03-2027 Spitzen Analytic Instruments Pvt. Ltd., V, Bldg No.4, Brahmand Complex, Phase, G-2, Ghodbunder Rd, Thane, Maharashtra 400708 Thane Maharashtra sales@spitzenanalytical.com 22-62231412 / 8
SR NO. COUNTRY NAME PATENT NUMBER
No Data Found.
SR NO. NAME STANDARD NUMBER LOGO
No Data Found.

General License Fee : ₹ 300,000.00 (Three Lakh)

General Royalty : 0%