-A A +A

This link shall take you to a page/website outside this website. For any query regarding the contents of the linked page/website, please contact the webmaster of the concerned website.

If you have already registered as a licensee then click on SIGN IN otherwise click on SIGN UP for register as a licensee.

60 kW RF Broadband Dual Directional Coupler


Figure 1: Developed 60 kW RF Broadband Dual Directional Coupler

Figure 1: Developed 60 kW RF Broadband Dual Directional Coupler

Directional Coupler is an indispensable measurement tool that provides a convenient and accurate means of sampling of RF energy in high power RF systems. Unlike other method of power sampling, Directional coupler also provides important capability of separating travelling waves in forward and reverse direction, thus enabling measurement of power levels in both directions to be precise. Especially when high power levels are involved, a Directional coupler should provide a low power signal, without any adjustment parts, that should be in the measurement range of RF sensor. For High power RF systems, RF power monitoring at multiple interfaces is a must requirement, especially with High Q RF resonators, for RF system commissioning, troubleshooting and continuous health monitoring. This is achieved with the help of high-power Directional Coupler, mostly procured from outside the country.

APPLICATIONS

  • Forward and reflected RF measurement of High-power systems.
Figure 1: Developed 60 kW RF Broadband Dual Directional Coupler

1 Figure 1: Developed 60 kW RF Broadband Dual Directional Coupler

Directional Coupler is an indispensable measurement tool that provides a convenient and accurate means of sampling of RF energy in high power RF systems. Unlike other method of power sampling, Directional coupler also provides important capability of separating travelling waves in forward and reverse direction, thus enabling measurement of power levels in both directions to be precise. Especially when high power levels are involved, a Directional coupler should provide a low power signal, without any adjustment parts, that should be in the measurement range of RF sensor. For High power RF systems, RF power monitoring at multiple interfaces is a must requirement, especially with High Q RF resonators, for RF system commissioning, troubleshooting and continuous health monitoring.

TECHNICAL SPECIFICATIONS

Type and Applications

  • Device Type
    60 kW CW Dual Directional coupler
  • Coupler
    Rigid coaxial main line and stripline as secondary line
  • Function
    Thru-line forward and Reflected RF power measurement
  • Application
    Specially suited for monitoring of Dynamic VSWR RF termination in high power RF system

RF Performance

  • Frequency Range : 300 MHz to 700 MHz
  • Average Power rating : 60 kW max.
  • Thruline VSWR : â‰¤ 1.2
  • Insertion Loss : â‰¤ 0.1 dB
  • Probes : 2
  • Measurement Range : 1 W to 60 kW CW and 1 W to 200 kW Pulsed (25% duty cycle)
  • Typical measurement Accuracy : Â±0.1 dB maximum in full range
  • Coupling : 45 dB to 55 dB
  • Typical Directivity : 20 dB min
  • Interface Connections : EIA 6 1/8 inch Female
  • Interface direction : straight

Physical Specifications

  • Size with RF connectors : 320 mm x 210 mm X 210 mm (length X width X height)
  • Gross Weight : â‰¤ 10 Kg
Figure 1: Developed 60 kW RF Broadband Dual Directional Coupler

1 Figure 1: Developed 60 kW RF Broadband Dual Directional Coupler

Directional Coupler is an indispensable measurement tool that provides a convenient and accurate means of sampling of RF energy in high power RF systems. Unlike other method of power sampling, Directional coupler also provides important capability of separating travelling waves in forward and reverse direction, thus enabling measurement of power levels in both directions to be precise. Especially when high power levels are involved, a Directional coupler should provide a low power signal, without any adjustment parts, that should be in the measurement range of RF sensor. For High power RF systems, RF power monitoring at multiple interfaces is a must requirement, especially with High Q RF resonators, for RF system commissioning, troubleshooting and continuous health monitoring. This is achieved with the help of high-power Directional Coupler, mostly procured from outside the country. There is a huge requirement of such high-power Directional couplers for ongoing as well as forth coming DAE projects.

For this coupled line Directional Coupler, rectangular cross-section coaxial transmission line has been used. Two asymmetric lines have been used as auxiliary lines on both sides of primary rectangular coaxial line. Rectangular ground planes, also incorporating continuous aperture for sampling of RF power, for both sides of primary line, have been implemented separately enabling ease of fabrication and RF shielding of electromagnetic field of primary line. Secondary line rests on this ground plane seamlessly further providing additional RF shield for primary line. Coaxial transitions, from EIA 6 1/8 inch flanged cylindrical coaxial line to this rectangular coaxial line, are also designed on both sides of primary rectangular coaxial line to for its seamless integration in standard high power RF systems.

TECHNICAL SPECIFICATIONS

Type and Applications

  • Device Type
    60 kW CW Dual Directional coupler
  • Coupler
    Rigid coaxial main line and stripline as secondary line
  • Function
    Thru-line forward and Reflected RF power measurement
  • Application
    Specially suited for monitoring of Dynamic VSWR RF termination in high power RF system

RF Performance

  • Frequency Range : 300 MHz to 700 MHz
  • Average Power rating : 60 kW max.
  • Thruline VSWR : â‰¤ 1.2
  • Insertion Loss : â‰¤ 0.1 dB
  • Probes : 2
  • Measurement Range : 1 W to 60 kW CW and 1 W to 200 kW Pulsed (25% duty cycle)
  • Typical measurement Accuracy : Â±0.1 dB maximum in full range
  • Coupling : 45 dB to 55 dB
  • Typical Directivity : 20 dB min
  • Interface Connections : EIA 6 1/8 inch Female
  • Interface direction : straight

Physical Specifications

  • Size with RF connectors : 320 mm x 210 mm X 210 mm (length X width X height)
  • Gross Weight : â‰¤ 10 Kg

TYPICAL END USERS

It is a thru-line bidirectional coupler thus it can be used for measuring RF power while system is working (without terminating) and monitoring line or load condition in various RF systems used for strategic applications. For example, application in solid-state high-power amplifier systems can be quoted, where a huge requirement exists for accurate and reliable measurement of forward as well as reflected powers of the amplifier modules. It finds uses for cellular base stations, military radar communications, global positioning systems etc.

List of important users of directional sensor are as follows:

  1. RRCAT, DAE, Indore
  2. VECC, DAE, Kolkata
  3. LRDE, DRDO, Bangalore
  4. DLRL, DRDO, Hyderabad
  5. Micropack limited, Bangalore
  6. ECIL Hyderabad
  7. HAL, Hyderabad
  8. Asthra microwave products, Hyderabad
  9. Data Pattern Chennai

MANPOWER REQUIREMENT

  • Technical Supervisor (Diploma in Electrical/Electronic Engg.) : 1
  • Operators/Technician (ITI) : 1
SR NO. Organization name Licensee Name Licensee Code ACQUIRED ON Valid Till Address City State Email Phone
01 M/s Minit Overseas Pvt. Ltd. Nishant Pandey 242 23-10-2019 22-10-2024 BF-4, Scheme-74C, Vijay Nagar, Indore Indore Madhya Pradesh minitoverseas2010@gmail.com 09303239361
SR NO. COUNTRY NAME PATENT NUMBER
No Data Found.
SR NO. NAME STANDARD NUMBER LOGO
No Data Found.

General License Fee : ₹ 100,000.00 (One Lakh)

General Royalty : 0%